Skip to main content

Research Repository

Advanced Search

Outputs (33)

Propofol detection for monitoring of intravenous anaesthesia: A review (2021)
Journal Article
Ferrier, D., Kiely, J., & Luxton, R. (2022). Propofol detection for monitoring of intravenous anaesthesia: A review. Journal of Clinical Monitoring and Computing, 36, 315-323. https://doi.org/10.1007/s10877-021-00738-5

This paper presents a review of established and emerging methods for detecting and quantifying the intravenous anaesthetic propofol in solution. There is growing evidence of numerous advantages of total intravenous anaesthesia using propofol compared... Read More about Propofol detection for monitoring of intravenous anaesthesia: A review.

Recent progress in screen-printed electrochemical sensors and biosensors for the detection of estrogens (2021)
Journal Article
Musa, A. M., Kiely, J., Luxton, R., & Honeychurch, K. C. (2021). Recent progress in screen-printed electrochemical sensors and biosensors for the detection of estrogens. Trends in Analytical Chemistry, 139, Article 116254. https://doi.org/10.1016/j.trac.2021.116254

Estrogens have become increasingly prevalent in environmental samples across the world, posing a serious threat to human health. They have received considerable public attention due to their harmful effect on the normal endocrine functions of humans... Read More about Recent progress in screen-printed electrochemical sensors and biosensors for the detection of estrogens.

Classification of the mechanism of toxicity as applied to human cell line ECV304 (2020)
Journal Article
Djawad, Y. A., Kiely, J., & Luxton, R. (2021). Classification of the mechanism of toxicity as applied to human cell line ECV304. Computer Methods in Biomechanics and Biomedical Engineering, 24(9), 933-944. https://doi.org/10.1080/10255842.2020.1861255

© 2020 Informa UK Limited, trading as Taylor & Francis Group. The objective of this study was to identify the pattern of cytotoxicity testing of the human cell line ECV304 using three techniques of an ensemble learning algorithm (bagging, boosting... Read More about Classification of the mechanism of toxicity as applied to human cell line ECV304.

Sensor (2020)
Patent
Allainguillaume, J., Barnett, J., Luxton, R., & Kiely, J. Sensor. WO 2020/089607 A1

The present invention relates to detecting viral infections in plants, especially Cacao swollen-shoot virus (CSSV) infections. Recombinant viral coat protein antigens and binding reagents that specifically bind to thereto are provided together with a... Read More about Sensor.

A non-contact impedimetric biosensing system for classification of toxins associated with cytotoxicity testing (2020)
Journal Article
Gasser, A., Eveness, J., Kiely, J., Attwood, D., & Luxton, R. (2020). A non-contact impedimetric biosensing system for classification of toxins associated with cytotoxicity testing. Bioelectrochemistry, 133, 107448. https://doi.org/10.1016/j.bioelechem.2019.107448

© 2019 We report on a novel impedance spectroscopy measurement and data analysis technique for cytotoxicity testing. The technique combines non-contact measurement with real-time impedance data analysis based on the toxin dose dependency of the outpu... Read More about A non-contact impedimetric biosensing system for classification of toxins associated with cytotoxicity testing.

Initial trail results of a magnetic biosensor for the rapid detection of Porcine Reproductive and Respiratory Virus (PRRSV) infection (2019)
Journal Article
Barnett, J. M., Monnier, B. M., Tyler, S., West, D., Ballantine-Dykes, H., Regan, E., …Luxton, R. (2020). Initial trail results of a magnetic biosensor for the rapid detection of Porcine Reproductive and Respiratory Virus (PRRSV) infection. Sensing and Bio-Sensing Research, 27, 100315. https://doi.org/10.1016/j.sbsr.2019.100315

© 2019 The resonant coil magnetometer quantifies paramagnetic particles (PMPs) and has been used to develop magneto-immunoassays in a range of formats. The advantage of magneto-immunoassays is that they are relatively inexpensive, portable, easy to p... Read More about Initial trail results of a magnetic biosensor for the rapid detection of Porcine Reproductive and Respiratory Virus (PRRSV) infection.

CSSV biosensor (WO2020089607-PAMPH-20200507-8395) (2019)
Patent
Allainguillaume, J., Barnett, J. M., Kiely, J., & Luxton, R. (in press). CSSV biosensor (WO2020089607-PAMPH-20200507-8395). WO 2020/089607 A1

The present invention relates to detecting viral infections in plants, especially Cacao swollen-shoot virus (CSSV) infections. Recombinant viral coat protein antigens and binding reagents that specifically bind to thereto are provided together with a... Read More about CSSV biosensor (WO2020089607-PAMPH-20200507-8395).

C3bio Poster AM KH RL JK 2019 (2019)
Presentation / Conference
Musa, A., Honeychurch, K., Kelly, J., & Luxton, R. (2019, September). C3bio Poster AM KH RL JK 2019

Bioinspired materials have emerged as alternatives to antibodies and enzymes in biosensor for environmental monitoring These are tailored made in order to mimics the molecular function of a natural receptors in biosensor Aptamers and Molecularly imp... Read More about C3bio Poster AM KH RL JK 2019.

A copper oxide/zinc oxide composite nano-surface for use in a biosensor (2019)
Journal Article
Cao, L., Kiely, J., Piano, M., & Luxton, R. (2019). A copper oxide/zinc oxide composite nano-surface for use in a biosensor. Materials, 12(7), 1126. https://doi.org/10.3390/ma12071126

© 2019 by the authors. In this study, biosensors based on zinc oxide-copper oxide composite nano-surfaces were prepared using a simple and inexpensive distributed colloidal technique. Combinations of mixed dispersions with volume ratios of 1:1, 1:2 a... Read More about A copper oxide/zinc oxide composite nano-surface for use in a biosensor.

The application of detrended fluctuation analysis to assess physical characteristics of the human cell line ECV304 following toxic challenges (2019)
Journal Article
Djawad, Y. A., Attwood, D., Kiely, J., & Luxton, R. (2019). The application of detrended fluctuation analysis to assess physical characteristics of the human cell line ECV304 following toxic challenges. Sensing and Bio-Sensing Research, 23, Article 100269. https://doi.org/10.1016/j.sbsr.2019.100269

© 2019 In this paper we present a non-contact, impedance-based sensor system capable of characterizing the toxic response of cells to three different types of toxin. ECV304 cells were treated with 1 mM Hydrogen peroxide, 5% Dimethyl Sulfoxide, and 10... Read More about The application of detrended fluctuation analysis to assess physical characteristics of the human cell line ECV304 following toxic challenges.