Skip to main content

Research Repository

Advanced Search

All Outputs (114)

Sensors/biosensors, based on screen-printing technology for biomedical applications (2003)
Journal Article
Ryan, S. L., Hart, J. P., Abass, A., Honeychurch, K. C., Pemberton, R., & Wedge, R. (2003). Sensors/biosensors, based on screen-printing technology for biomedical applications. Indian Journal of Chemistry.section A.inorganic, Physical, Theoretical && Analytical, 42A(4), 709-718

This article describes three recent developments from our laboratory, in which screen-printed carbon electrodes have been modified in order to develop sensors/biosensors for analytes of biomedical importance. The analytical applications described are... Read More about Sensors/biosensors, based on screen-printing technology for biomedical applications.

Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode (2002)
Journal Article
Honeychurch, K. C., Hawkins, D. M., Hart, J. P., & Cowell, D. C. (2002). Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode. Talanta, 57(3), 565-574. https://doi.org/10.1016/S0039-9140%2802%2900060-7

Screen-printed carbon electrodes (SPCEs), without chemical modification, have been investigated as disposable sensors for the measurement of trace levels of Cu2+. Cyclic voltammetry was employed to elucidate the electrochemical behaviour of Cu2+ at t... Read More about Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode.

Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode (2002)
Journal Article
Arrigan, D. W., Cowell, D. C., Hart, J. P., Honeychurch, K. C., Honeychurch, K. C., Hawkins, D. M., …Cowell, D. C. (2002). Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode. Electroanalysis, 14(3), 177-185. https://doi.org/10.1002/1521-4109%28200202%2914%3A3%3C177%3A%3AAID-ELAN177%3E3.0.CO%3B2-V

Screen-printed carbon electrodes (SPCEs) have been evaluated for the anodic stripping voltammetric determination of cadmium using open circuit accumulation facilitated by two different calixarenes: a novel thiolated calixarene, calixarene (I), (5,11,... Read More about Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode.

Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode (2002)
Journal Article
Honeychurch, K. C., Hart, J. P., Cowell, D. C., & Arrigan, D. W. (2002). Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode. Electroanalysis, 14(3), 177-185. https://doi.org/10.1002/1521-4109%28200202%2914%3A3%3C177%3A%3AAID-ELAN177%3E3.0.CO%3B2-V

Screen-printed carbon electrodes (SPCEs) have been evaluated for the anodic stripping voltammetric determination of cadmium using open circuit accumulation facilitated by two different calixarenes: a novel thiolated calixarene, calixarene (I), (5,11,... Read More about Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode.

Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs (2001)
Journal Article
McCalley, D. V., Luxton, R. W., Bird, D. J., Hart, J. P., Kirsch, N., Kirsch, N., …McCalley, D. V. (2001). Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs. Analyst, 126(11), 1936-1941. https://doi.org/10.1039/b108008n

This paper describes the fabrication of a sensor for 1-hydroxypyrene (1-OHP) based on a screen-printed carbon electrode (SPCE) modified with a molecularly imprinted polymer (MIP); 1-OHP was chosen as a model metabolite of polyaromatic hydrocarbons (P... Read More about Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs.

Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry (2001)
Journal Article
Arrigan, D. W., Cowell, D. C., Hart, J. P., Honeychurch, K. C., Honeychurch, K. C., Hart, J. P., …Arrigan, D. W. (2001). Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry. Sensors and Actuators B: Chemical, 77(3), 642-652. https://doi.org/10.1016/S0925-4005%2801%2900778-X

Screen-printed carbon electrodes (SPCEs) have been modified with two different calixarenes; a novel thiolated calixarene (5,11,17,23,tetra-tert-butyl-25,26,27,28-tetrakis(2-mercaptoethoxy)- calix[4]arene), and the commercially available 25,26,27,28-t... Read More about Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry.

Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry (2001)
Journal Article
Honeychurch, K. C., Hart, J. P., & Cowell, D. C. (2001). Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry. Analytica Chimica Acta, 431(1), 89-99. https://doi.org/10.1016/S0003-2670%2800%2901294-0

A method for the trace determination of Pb2+, using a disposable 1-(2-pyridylazo)-2-naphthol (PAN) drop-coated modified screen-printed carbon electrode (PAN-SPCE), has been developed. Lead ions (Pb2+) are accumulated from ammonia buffer, on the PAN-S... Read More about Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry.

Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry (2001)
Journal Article
Honeychurch, K. C., Hart, J. P., & Cowell, D. C. (2001). Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry. Analytica Chimica Acta, 431(1), 89-99. https://doi.org/10.1016/S0003-2670%2800%2901294-0

A method for the trace determination of Pb2+, using a disposable 1-(2-pyridylazo)-2-naphthol (PAN) drop-coated modified screen-printed carbon electrode (PAN-SPCE), has been developed. Lead ions (Pb2+) are accumulated from ammonia buffer, on the PAN-S... Read More about Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry.

Voltammetric behavior and trace determination of lead at a mercury-free screen-printed carbon electrode (2000)
Journal Article
Honeychurch, K. C., Hart, J. P., & Cowell, D. C. (2000). Voltammetric behavior and trace determination of lead at a mercury-free screen-printed carbon electrode. Electroanalysis, 12(3), 171-177. https://doi.org/10.1002/%28SICI%291521-4109%28200002%2912%3A3%3C171%3A%3AAID-ELAN171%3E3.0.CO%3B2-Q

Abstract Screen-printed carbon electrodes (SPCEs), without chemical modification, have been investigated as disposable sensors for the measurement of trace levels of Pb. Cyclic voltammetry was employed to elucidate the electrochemical behavior of Pb... Read More about Voltammetric behavior and trace determination of lead at a mercury-free screen-printed carbon electrode.

A pilot-plant study of an automated quality control electronic nose for the monitoring of dry cured hams (1999)
Book Chapter
Abbass, A., de Lacy Costello, B., Cooper, L., Evans, P., Ewen, R., Hart, J. P., & Ratcliffe, N. M. (1999). A pilot-plant study of an automated quality control electronic nose for the monitoring of dry cured hams. In W. Hurst (Ed.), Electronic Noses & Sensor Array Based Systems - Design & Applications, Fifth International Symposium Proceedings (211-224). Pennsylvania, USA: CRC Press

A reagentless, screen-printed amperometric biosensor for the determination of glutamate in food and clinical applications
Book Chapter
Hughes, G., Pemberton, R., Fielden, P., & Hart, J. (2017). A reagentless, screen-printed amperometric biosensor for the determination of glutamate in food and clinical applications. In A. Rasooly, & B. Prickril (Eds.), Biosensors and Biodetection. Springer

A reagentless biosensor has been successfully developed to measure glutamate in food and clinical samples. The enzyme, glutamate dehydrogenase (GLDH) and the cofactor, nicotinamide adenine dinucleotide (NAD+) are fully integrated onto the surface of... Read More about A reagentless, screen-printed amperometric biosensor for the determination of glutamate in food and clinical applications.