Skip to main content

Research Repository

Advanced Search

All Outputs (125)

Grasping force prediction based on sEMG signals (2020)
Journal Article
Ma, R., Zhang, L., Li, G., Jiang, D., Xu, S., & Chen, D. (2020). Grasping force prediction based on sEMG signals. Alexandria Engineering Journal, 59(3), 1135-1147. https://doi.org/10.1016/j.aej.2020.01.007

In order to realize the force control, when the prosthetic hand grasps the object, the forearm electromyography signal is collected by the multi-channel surface electromyography (sEMG) acquisition system. The grasping force information of the human h... Read More about Grasping force prediction based on sEMG signals.

Development of efficient electroactive biofilm in urine-fed microbial fuel cell cascades for bioelectricity generation (2020)
Journal Article
Obata, O., Salar-Garcia, M. J., Greenman, J., Kurt, H., Chandran, K., & Ieropoulos, I. (2020). Development of efficient electroactive biofilm in urine-fed microbial fuel cell cascades for bioelectricity generation. Journal of Environmental Management, 258, Article 109992. https://doi.org/10.1016/j.jenvman.2019.109992

The Microbial fuel cell (MFC) technology harnesses the potential of some naturally occurring bacteria for electricity generation. Digested sludge is commonly used as the inoculum to initiate the process. There are, however, health hazards and practic... Read More about Development of efficient electroactive biofilm in urine-fed microbial fuel cell cascades for bioelectricity generation.

A non-contact impedimetric biosensing system for classification of toxins associated with cytotoxicity testing (2020)
Journal Article
Gasser, A., Eveness, J., Kiely, J., Attwood, D., & Luxton, R. (2020). A non-contact impedimetric biosensing system for classification of toxins associated with cytotoxicity testing. Bioelectrochemistry, 133, 107448. https://doi.org/10.1016/j.bioelechem.2019.107448

© 2019 We report on a novel impedance spectroscopy measurement and data analysis technique for cytotoxicity testing. The technique combines non-contact measurement with real-time impedance data analysis based on the toxin dose dependency of the outpu... Read More about A non-contact impedimetric biosensing system for classification of toxins associated with cytotoxicity testing.

U -Model-Based Finite-Time Control for Nonlinear Valve-Controlled Hydraulic Servosystem (2020)
Journal Article
Yan, H., Li, J., Nouri, H., & Xu, L. (2020). U -Model-Based Finite-Time Control for Nonlinear Valve-Controlled Hydraulic Servosystem. Mathematical Problems in Engineering, 2020, 1-12. https://doi.org/10.1155/2020/7083639

© 2020 Hao Yan et al. Valve-controlled servosystems are widely used in dynamic tracking, but, not properly studied, nonlinearity, perturbation of internal parameters, and external disturbance have significant impacts on the control performance and ch... Read More about U -Model-Based Finite-Time Control for Nonlinear Valve-Controlled Hydraulic Servosystem.