Roy Pemberton Roy.Pemberton@uwe.ac.uk
Senior Lecturer
Fabrication of microband glucose biosensors using a screen-printing water-based carbon ink and their application in serum analysis
Pemberton, Roy; Pittson, R.; Hart, John P.; Biddle, N.
Authors
R. Pittson
John Hart John.Hart@uwe.ac.uk
Professor
N. Biddle
Abstract
Microband glucose biosensors were fabricated by screen-printing a water-based carbon ink formulation containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, then insulating and sectioning through the thick (20 μm) film to expose a 3 mm-long working electrode edge. The performance of these biosensors for glucose analysis was investigated at 25 °C. Voltammetry in glucose-containing buffer solutions established that an operating potential of +0.4 V vs. Ag/AgCl was suitable for analysis under both stirring and quiescent conditions. The influence of pH on biosensor performance was established and an operational pH of 8.0 was selected. Steady-state responses were obtained under quiescent conditions, suggesting a mixed mechanism predominated by radial diffusion, indicative of microelectrode behaviour. Calibration studies obtained with these biosensors showed steady-state currents that were linearly dependent on glucose concentration from the limit of detection (0.27 mM) up to 2.0 mM, with a precision for replicate biosensors of 6.2-10.7%. When applied to the determination of glucose in human serum, the concentration compared favourably to that determined by a spectroscopic method. These results have demonstrated a simple means of fabricating biosensors for glucose measurement and determination in situations where low-current real-time monitoring under quiescent conditions would be desirable. © 2008 Elsevier B.V. All rights reserved.
Journal Article Type | Article |
---|---|
Publication Date | Jan 1, 2009 |
Journal | Biosensors and Bioelectronics |
Print ISSN | 0956-5663 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 24 |
Issue | 5 |
Pages | 1246-1252 |
DOI | https://doi.org/10.1016/j.bios.2008.07.035 |
Keywords | glucose biosensor, screen-printing, water-based carbon ink, microband electrode |
Public URL | https://uwe-repository.worktribe.com/output/999345 |
Publisher URL | http://dx.doi.org/10.1016/j.bios.2008.07.035 |
You might also like
Downloadable Citations
About UWE Bristol Research Repository
Administrator e-mail: repository@uwe.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search