Abstract

Beam‐column joints (BCJs) constructed until the 1970s carry a low shear capability due to the absence of shear reinforcement. Fiber‐reinforced polymers (FRP) are more reliable than other materials to strengthen a weak BCJ. To date, plenty of analytical models have been developed to analyze the actual contribution of the FRP to the shear strength of RC BCJs. However, the models developed are either too complex in computational efforts or based on empirical coefficients that result in compromised results. The models that formulate the contribution of FRP to the shear strength of the FRP‐strengthened deficient interior BCJ are very limited, and such models are too complex. An adequate BCJs’ FRP strain equation must still be developed to address these issues. Therefore, the FRP effective strain equation and contribution of FRP to RC BCJs are derived in this research work using an updated database of the appropriate BCJs. The initial analytical model of Bousselham, which Del Vecchio later improved, is further extended to FRP‐strengthened deficient interior BCJs. For this purpose, an updated database of the 32 tests around the world of FRP-strengthened interior BCJs deficient in seismic reinforcement is prepared. Firstly, the experimental effective FRP strain is derived using the experimental database. Then, a power‐type equation is derived for the effective FRP strain by considering the crucial parameters of the FRP‐strengthened interior BCJs. Finally, the experimental shear strengths and those determined with the proposed equation of the FRP‐strengthened joints are compared. The average ratio between the experimental and analytical (proposed model) joint shear strengths of the considered specimens ensured the accuracy of the suggested model. The suggested approach makes computing the FRP enhancements required to avoid shear failure in interior joints easy and reliable for researchers and field engineers interested in seismically reinforcing existing structures.

Citation

Zia, A., Pu, Z., Holly, I., Umar, T., & Tariq, M. A. U. R. (2022). Development of an analytical model for the FRP retrofitted deficient interior reinforced concrete beam-column joints. Applied Sciences, 12(5), Article 2339. https://doi.org/10.3390/app12052339

Journal Article Type Article
Acceptance Date Feb 22, 2022
Online Publication Date Feb 23, 2022
Publication Date Feb 23, 2022
Deposit Date Feb 23, 2022
Publicly Available Date Feb 23, 2022
Journal Applied Sciences
Electronic ISSN 2076-3417
Publisher MDPI
Peer Reviewed Peer Reviewed
Volume 12
Issue 5
Article Number 2339
Series Title Special Issue Advances in Stone, Clay, Glass, Epoxy and Concrete
Series ISSN 2076-3417
DOI https://doi.org/10.3390/app12052339
Keywords FRP strengthening; analytical model; under‐designed RC joints; effective FRP strain; interior beam‐column joints
Public URL https://uwe-repository.worktribe.com/output/9052741
Publisher URL https://www.mdpi.com/2076-3417/12/5/2339

Files







You might also like



Downloadable Citations