The effect of DBSA/KCl on peroxide determination at silver screen-printed electrodes
(2012)
Presentation / Conference Contribution
Prof. Tony Killard's Outputs (97)
Development of a biosensor for HDL-cholesterol based on a novel electrocatalyst for hydrogen peroxide reduction (2012)
Presentation / Conference Contribution
A printed electrocatalyst for the measurement of H2O2 formed via enzymatic oxidation (2012)
Presentation / Conference Contribution
Printed electronic devices for diagnostic applications (2012)
Presentation / Conference Contribution
Electrochemical sensor strips were one of the first devices to become a global success in what might now be termed the printed electronics industry. Since their creation some 20 years ago, printed sensor strips are used extensively for a range of cli... Read More about Printed electronic devices for diagnostic applications.
Electrochemical detection of hydrogen peroxide in stressed plant cells (2012)
Presentation / Conference Contribution
Advanced diagnostic device technologies (2012)
Presentation / Conference Contribution
SIMS: A Smart integrated miniaturised sensor system (2012)
Presentation / Conference Contribution
New developments in printed biosensors for clinical and diagnostic applications (2012)
Presentation / Conference Contribution
Electrochemical sensor strips were one of the first devices to become a global success in what might now be termed the printed electronics industry. Since their creation some 20 years ago, printed sensor strips are used extensively for a range of cli... Read More about New developments in printed biosensors for clinical and diagnostic applications.
A Printed Electrocatalyst for Hydrogen Peroxide Reduction (2012)
Journal Article
The modification of silver screen-printed electrodes with a dodecyl benzenesulfonic acid and KCl solution was performed by inkjet printing. Scanning Electron Microscopy was performed to characterize the electrode surfaces. Electrochemical reduction o... Read More about A Printed Electrocatalyst for Hydrogen Peroxide Reduction.
Heparin monitoring: From blood tube to microfluidic device (2012)
Book Chapter
Heparin anticoagulant therapy has been pivotal in both the treatment and prophylaxis of thrombotic disease for many decades. It remains standard practice to monitor unfractionated heparin (UFH) therapy due to its unpredictable pharmacokinetics. The a... Read More about Heparin monitoring: From blood tube to microfluidic device.
Effects of four commercially available factor Xa proteins on the fluorogenic anti-factor Xa assay when monitoring unfractionated heparin (2012)
Journal Article
Four commercially available factor Xa (FXa) reagents were evaluated in a fluorogenic anti-FXa assay. The four reagents - of which three were of human origin and the fourth was bovine - were compared in terms of the resulting assay dynamic ranges, lag... Read More about Effects of four commercially available factor Xa proteins on the fluorogenic anti-factor Xa assay when monitoring unfractionated heparin.
Quantification of unfractionated heparin in human plasma and whole blood by means of novel fluorogenic anti-FXa assays (2011)
Journal Article
Novel and sensitive plate-based fluorogenic anti-factor Xa (FXa) assays were investigated to quantify unfractionated heparin (UFH) in human plasma and whole blood within the therapeutic ranges of 0-1.6. U/mL and 0-0.8. U/mL, respectively. Two fluorog... Read More about Quantification of unfractionated heparin in human plasma and whole blood by means of novel fluorogenic anti-FXa assays.
Comparison of a fluorogenic anti-FXa assay with a central laboratory chromogenic anti-FXa assay for measuring LMWH activity in patient plasmas (2011)
Journal Article
Introduction: Low molecular weight heparins (LMWHs) are used worldwide for the treatment and prophylaxis of thromboembolic disorders. Routine laboratory tests are not required due to the predictable pharmacokinetics of LMWHs, with the exception of pr... Read More about Comparison of a fluorogenic anti-FXa assay with a central laboratory chromogenic anti-FXa assay for measuring LMWH activity in patient plasmas.
Comparison of the anticoagulant response of a novel fluorogenic anti-FXa assay with two commercial anti-FXa chromogenic assays (2011)
Journal Article
Introduction: Fast and accurate monitoring is crucial in the successful regulation of coagulation therapy. For the treatment of venous thromboembolism, both unfractionated heparin (UFH) and low molecular weight heparins (LMWHs) are commonly administe... Read More about Comparison of the anticoagulant response of a novel fluorogenic anti-FXa assay with two commercial anti-FXa chromogenic assays.
New developments in printable biosensors (2011)
Presentation / Conference Contribution
Printed polyaniline-modified interdigitated electrodes for detection and quantification of ammonia in breath (2011)
Presentation / Conference Contribution
A range of pathological conditions can lead to elevated blood ammonia and urea nitrogen levels. These include kidney and liver dysfunction and urea cycle defects. These conditions result in severe reduction in quality and quantity of life. Blood nitr... Read More about Printed polyaniline-modified interdigitated electrodes for detection and quantification of ammonia in breath.
Electrochemical sensing devices: From printed materials to printed integration (2011)
Presentation / Conference Contribution
In an analogy with silicon-based electronics, novel sensing and biosensing technologies must keep pace with the demands of increased sophistication, greater functionality, improved performance, and greater intelligence while still being low cost and... Read More about Electrochemical sensing devices: From printed materials to printed integration.
Wholly printed polypyrrole-based biosensor on flexible substrate (2011)
Presentation / Conference Contribution
Inkjet-printed polyaniline nanoparticle electrodes for detection and quantification of ammonia in breath (2011)
Presentation / Conference Contribution
Printed sensor devices: From materials fabrication to commercial applications (2011)
Presentation / Conference Contribution