James Robson
Direct thermal desorption gas chromatographic determination of toxicological relevant concentrations of ethylene glycol in whole blood
Robson, James; Townsend, Stephen; Bowdler, Paul; Honeychurch, Kevin C
Authors
Stephen Townsend
Paul Bowdler
Kevin Honeychurch Kevin.Honeychurch@uwe.ac.uk
Senior Lecturer in Forensic Science
Abstract
Ethylene Glycol has been determined directly in whole blood using thermal desorption gas chromatography. Recoveries of between 84.8 % to 107 % were recorded, with corresponding %CV of between 1.7 % and 5.8 %. No extraction or derivatization steps were required.
Citation
Robson, J., Townsend, S., Bowdler, P., & Honeychurch, K. C. (2018, April). Direct thermal desorption gas chromatographic determination of toxicological relevant concentrations of ethylene glycol in whole blood. Paper presented at CRIB Annual Meeting 2018
Presentation Conference Type | Conference Paper (unpublished) |
---|---|
Conference Name | CRIB Annual Meeting 2018 |
Start Date | Apr 20, 2018 |
End Date | Apr 20, 2018 |
Acceptance Date | Apr 20, 2018 |
Peer Reviewed | Peer Reviewed |
Keywords | ethylene glycol, thermal desorption gas chromatography, whole blood |
Public URL | https://uwe-repository.worktribe.com/output/869311 |
Additional Information | Title of Conference or Conference Proceedings : CRIB Annual Meeting 2018 |