Skip to main content

Research Repository

Advanced Search

Development of an on-column trace enrichment method for the determination of sub-μg/L bisphenol A in bottled water by RP-HPLC with fluorescent detection

Honeychurch, Kevin C.

Development of an on-column trace enrichment method for the determination of sub-μg/L bisphenol A in bottled water by RP-HPLC with fluorescent detection Thumbnail


Authors



Abstract

A simple extraction-free, on-column trace enrichment liquid chromatographic method for the determination of trace levels of bisphenol A (BPA) in bottled water samples has been developed. It was found possible to determine ng/L (ppt) levels of BPA by the direct introduction of 6 mL of sample water to the HPLC column utilising fluorescence detection (Exλ = 274 nm, Emλ = 314 nm). Following the loading of the sample and the chromatographic focusing of the BPA on the analytical column, a simple switch from the aqueous sample to the isocratic chromatographic elution step of 50% acetonitrile/deionised water was undertaken. Using a BPA concentration of 0.596 μg/L the effect of sample volume was investigated over the range 1.0 to 12 mL. A linear relationship with the sample volume introduced to the HPLC column and the resulting peak height for BPA was found over the entire range investigated R2=0.999. Using a sample volume of 6.0 mL, a well-defined chromatographic peak was recorded for BPA over the concentration range of 0.1 μg/L to 6.25 μg/L R2=0.9998. A limit of detection of 0.058 μg/L for BPA was calculated based on 3 δ. A mean recovery of 100% with an associated %CV of 7.6% (n = 5) was obtained for a bottled spring water sample fortified with 1.25 μg/L BPA. Samples can be processed in under 12 minutes, much faster than that commonly reported for conventional offline extraction and chromatographic-based methods. The results show that the optimised method holds promise for the determination of BPA in such samples.

Citation

Honeychurch, K. C. (2024). Development of an on-column trace enrichment method for the determination of sub-μg/L bisphenol A in bottled water by RP-HPLC with fluorescent detection. International Journal of Analytical Chemistry, 2024, Article 8258123. https://doi.org/10.1155/2024/8258123

Journal Article Type Article
Acceptance Date Jan 10, 2024
Online Publication Date Jan 24, 2024
Publication Date Jan 24, 2024
Deposit Date Jan 25, 2024
Publicly Available Date Feb 2, 2024
Journal International Journal of Analytical Chemistry
Print ISSN 1687-8760
Electronic ISSN 1687-8779
Publisher Hindawi
Peer Reviewed Peer Reviewed
Volume 2024
Article Number 8258123
DOI https://doi.org/10.1155/2024/8258123
Keywords Analytical Chemistry
Public URL https://uwe-repository.worktribe.com/output/11627943

Files




You might also like



Downloadable Citations