Skip to main content

Research Repository

Advanced Search

Validation of virtual reality simulation for obstetric ultrasonography: A prospective cross-sectional study

Fox, Robert; Burden, Christy; Preshaw, Jessica; White, Paul; Draycott, Timothy J.; Grant, Simon

Authors

Robert Fox

Christy Burden

Jessica Preshaw

Paul White Paul.White@uwe.ac.uk
Professor in Applied Statistics

Timothy J. Draycott

Simon Grant



Abstract

INTRODUCTION: Ultrasonography is an important skill for obstetricians and gynecologists; however, trainees have highlighted ultrasonography as an area of deficiency in their training. We undertook a prospective cross-sectional comparative study to assess content and construct validity of an ultrasound virtual reality (VR) simulator (UltraSim). METHODS: Twenty-six physicians and sonographers of varied ultrasonography experience were recruited and divided into trainees (no formal ultrasonography training) and expert (certified) categories. They performed a VR simulation crown-rump length (CRL) ultrasound scan and growth ultrasound scan measuring biparietal diameter, occipitofrontal diameter, abdominal anteroposterior and transverse diameters, and femur length. Maximum pool depth (MPD), placental site, and fetal presentation were also assessed. Outcome measures included the mean absolute deviation and the variance of the absolute deviation from true measurements. Accuracy of determining placental site, fetal presentation, and MPD was assessed. The time taken to perform each type of scan was recorded. RESULTS: Trainees had significantly greater variation of measurement of CRL (P = 0.025) than the expert group. For late-pregnancy fetal biometry, the absolute deviation and the degree of variability for all measurements differed. These differences were statistically significant (P < 0.05) for all measurements except abdominal diameters and MPD. Trainees took significantly longer time to obtain CRL and fetal biometric scans (P < 0.001). All subjects correctly identified fetal presentation and placental site. CONCLUSIONS: Clinicians with differing ultrasonography expertise showed differing skill with the UltraSim VR simulator, demonstrating construct validity for skills needed in simulation. Consideration should be given to investigating whether trainees with minimal scanning experience can improve their clinical skills and efficiency with VR simulation. Copyright © 2012 by the Society for Simulation in Healthcare.

Journal Article Type Article
Publication Date Oct 1, 2012
Journal Simulation in Healthcare
Print ISSN 1559-2332
Electronic ISSN 1559-713X
Publisher Lippincott, Williams & Wilkins
Peer Reviewed Peer Reviewed
Volume 7
Issue 5
Pages 269-273
DOI https://doi.org/10.1097/SIH.0b013e3182611844
Keywords virtual-reality simulation, obstetric ultrasonography
Public URL https://uwe-repository.worktribe.com/output/943166
Publisher URL http://dx.doi.org/10.1097/SIH.0b013e3182611844