T. Ahmadraji
Measurement of total cholesterol using an enzyme sensor based on a printed hydrogen peroxide electrocatalyst
Ahmadraji, T.; Killard, A. J.; Ahmadraji, Termeh; Killard, Anthony
Authors
A. J. Killard
Termeh Ahmadraji
Prof. Tony Killard Tony.Killard@uwe.ac.uk
Research Professor in Biomedical Sciences
Abstract
© 2016 The Royal Society of Chemistry. Cholesterol is a major modifiable risk factor in cardiovascular disease and can be effectively managed by a combination of medication and monitoring. There continues to be a need for new point-of-care diagnostics to measure lipid panels, including total cholesterol. Enzyme assays based on the generation of hydrogen peroxide have been very effective in this regard. This work demonstrates the application of printed electrochemical sensors to the measurement of total cholesterol in serum. The assay uses the surfactant Triton X-100 to provide electrocatalytic enhancement of a silver paste screen-printed electrode to hydrogen peroxide, while also achieving effective solubilisation of total cholesterol from lipoprotein. The resulting biosensors employed 0.5% (v/v) Triton X-100 in PBS with 156 U mL-1 cholesterol esterase and 60 U mL-1 cholesterol oxidase. Measurement of total cholesterol in serum in the range of 0 to 10 mM had a sensitivity of 2.24 × 10-8 A mM-1, with coefficient of determination of 0.984, detection limit of at least 2 mM and average relative standard deviation of 10.8% (n = 3).
Journal Article Type | Article |
---|---|
Acceptance Date | Mar 3, 2016 |
Publication Date | Apr 7, 2016 |
Deposit Date | Dec 16, 2016 |
Journal | Analytical Methods |
Print ISSN | 1759-9660 |
Electronic ISSN | 1759-9679 |
Publisher | Royal Society of Chemistry |
Peer Reviewed | Peer Reviewed |
Volume | 8 |
Issue | 13 |
Pages | 2743-2749 |
DOI | https://doi.org/10.1039/c6ay00468g |
Keywords | cholesterol, biosensor, enzyme sensor, hydrogen peroxide, electrocatalysis |
Public URL | https://uwe-repository.worktribe.com/output/912835 |
Publisher URL | http://dx.doi.org/10.1039/C6AY00468G |
Contract Date | Dec 16, 2016 |
You might also like
Downloadable Citations
About UWE Bristol Research Repository
Administrator e-mail: repository@uwe.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search