Skip to main content

Research Repository

Advanced Search

Assessment of optical quality of ready‐made reading spectacles for presbyopic correction

Asare, Frederick A.; Ahiakwao, Godwin A.; Oduro, Bright A.; Nti, Augustine N.

Assessment of optical quality of ready‐made reading spectacles for presbyopic correction Thumbnail


Authors

Frederick A. Asare

Godwin A. Ahiakwao

Bright A. Oduro

Augustine N. Nti



Abstract

Purpose
Many presbyopic patients in both developed and developing countries use ready-made reading spectacles for their near vision correction even though the quality of these spectacles cannot always be assured. This study assessed the optical quality of ready-made reading spectacles for presbyopic correction in comparison with relevant international standards.

Methods
A total of 105 ready-made reading spectacles with powers ranging from +1.50 to +3.50 dioptres (D) in +0.50 D steps were randomly procured from open markets in Ghana and assessed for their optical quality, including induced prisms and safety markings. These assessments were done in line with the International Organization for Standardization (ISO 16034:2002 [BS EN 14139:2010]) as well as the standards used in low-resource countries.

Results
All lenses (100%) had significant induced horizontal prism that exceeded the tolerance levels stipulated by the ISO standards, while 30% had vertical prism greater than the specified tolerances. The highest prevalence of induced vertical prism was seen in the +2.50 and +3.50 D lenses (48% and 43%, respectively). When compared with less conservative standards, as suggested for use in low-resource countries, the prevalence of induced horizontal and vertical prism reduced to 88% and 14%, respectively. While only 15% of spectacles had a labelled centration distance, none had any safety markings per the ISO standards.

Conclusion
The high prevalence of ready-made reading spectacles in Ghana that fail to meet optical quality standards indicates the need for more robust, rigorous and standardised protocols for assessing their optical quality before they are sold on the market. This will alleviate unwanted side effects including asthenopia associated with their use. There is also the need to intensify public health awareness on the use of ready-made reading spectacles, especially by patients with significant refractive errors and ocular pathologies.

Journal Article Type Article
Acceptance Date Jun 14, 2023
Online Publication Date Jun 28, 2023
Publication Date Nov 23, 2024
Deposit Date Oct 10, 2024
Publicly Available Date Oct 11, 2024
Journal Ophthalmic and Physiological Optics
Print ISSN 0275-5408
Electronic ISSN 1475-1313
Publisher Wiley
Peer Reviewed Peer Reviewed
Volume 43
Issue 6
Pages 1337-1343
DOI https://doi.org/10.1111/opo.13197
Public URL https://uwe-repository.worktribe.com/output/13278604

Files





You might also like



Downloadable Citations