K. C. Honeychurch
Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry
Honeychurch, K. C.; Hart, J. P.; Cowell, D. C.; Arrigan, D. W.M.; Honeychurch, Kevin C.; Hart, John P.; Cowell, David C.; Arrigan, Damien W.M.
Authors
J. P. Hart
D. C. Cowell
D. W.M. Arrigan
Dr Kevin Honeychurch Kevin.Honeychurch@uwe.ac.uk
Senior Lecturer in Forensic Science
John Hart John.Hart@uwe.ac.uk
Professor
David C. Cowell
Damien W.M. Arrigan
Abstract
Screen-printed carbon electrodes (SPCEs) have been modified with two different calixarenes; a novel thiolated calixarene (5,11,17,23,tetra-tert-butyl-25,26,27,28-tetrakis(2-mercaptoethoxy)- calix[4]arene), and the commercially available 25,26,27,28-tetrahydroxy-calix[4]arene. Both calixarene modified SPCEs (CAL-SPCEs) were evaluated for the trace determination of lead ions (Pb2+). Pb2+ were accumulated from ammonia buffer, on the CAL-SPCE surface by the formation of a chemical complex at open circuit. The resulting SPCE with complexed Pb2+ was then transferred to 0.1 M HCl and subjected to cyclic voltammetry to investigate the nature of the accumulation process. Further investigations were undertaken using differential pulse anodic stripping voltammetry (DPASV). Conditions were optimised with respect to the pH and concentration of the accumulation medium, preconcentration time and the mass of drop-coated calixarene. The thiolated calixarene was found superior in terms of sensitivity and further investigations were carried out on this CAL-SPCE. A 10 min preconcentration time, followed by DPASV resulted in a limit of detection of 5 ng ml-1, with a linear range to 100 ng ml-1 Pb2+. The method was evaluated by carrying out lead determinations on spiked river water samples at 14 ng ml-1; the mean recovery of Pb2+ was 95.9% and the coefficient of variation was found to be 8.4% (n = 5) using a separate CAL-SPCE for each determination. Therefore, the performance data suggests that the method is reliable at the concentrations examined in this study. © 2001 Elsevier Science B.V.
Journal Article Type | Article |
---|---|
Publication Date | Jul 10, 2001 |
Deposit Date | Aug 6, 2010 |
Journal | Sensors and Actuators, B: Chemical |
Print ISSN | 0925-4005 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 77 |
Issue | 3 |
Pages | 642-652 |
DOI | https://doi.org/10.1016/S0925-4005%2801%2900778-X |
Keywords | screen-printed carbon electrode; calixarene; differential pulse anodic stripping voltammetry; lead; chemically modified electrode |
Public URL | https://uwe-repository.worktribe.com/output/1086190 |
Publisher URL | http://dx.doi.org/10.1016/S0925-4005(01)00778-X |
Contract Date | Apr 21, 2016 |
You might also like
Downloadable Citations
About UWE Bristol Research Repository
Administrator e-mail: repository@uwe.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search