Abstract
A novel whole cell bacterial biosensor, which emits light in response to the active metabolite of cytosine arabinoside (ara-C, cytarabine), ara-CTP, has been investigated and verified. The biosensor has been formulated as an ex vivo assay, designed for peripheral blood or bone marrow cells, which can produce a clinical result within a working day. The nucleoside analogue ara-C is a key agent for treatment of acute myeloid leukaemia (AML); treatment decisions are made rapidly with AML, patients often receiving same-day commencement of chemotherapy. Currently no rapid predictive test is available to select appropriate therapy for patients prior to treatment. Experiments were designed to determine optimal assay conditions using leukaemic cell lines. We observed a significant increase (~15 fold) in bioluminescence signal compared to control after 8-h incubation of the biosensor with ara-C. This corresponded to a >2-log increase in light output per bacterial cell. Interestingly, bioluminescence conferred a survival advantage to the bacteria following ara-C treatment. The assay is sensitive (lower limit of quantitation of 0.05. μM), selective, accurate (≤15% RE) and precise (≤15% coefficient of variation) over a linear concentration range of ara-CTP (0.05-0.5. μM), and detection is independent of reaction volume. Recovery of added standard was tested using ex vivo patient leukaemic cells (n=5). Stability studies on lyophilized bacterial biosensor were performed to ensure maintenance of performance over 12 months. The biosensor assay could be invaluable to the clinician, assisting with treatment selection, and potentially mitigating the risks of resistance and toxicity observed with this drug. © 2013 Elsevier B.V.
Journal Article Type | Article |
---|---|
Acceptance Date | Sep 6, 2013 |
Publication Date | Feb 15, 2014 |
Journal | Biosensors and Bioelectronics |
Print ISSN | 0956-5663 |
Electronic ISSN | 1873-4235 |
Publisher | Elsevier |
Peer Reviewed | Peer Reviewed |
Volume | 52 |
Pages | 345-353 |
DOI | https://doi.org/10.1016/j.bios.2013.09.014 |
Keywords | whole cell biosensor, bioluminescent, leukaemia, chemotherapy |
Public URL | https://uwe-repository.worktribe.com/output/821121 |
Publisher URL | http://dx.doi.org/10.1016/j.bios.2013.09.014 |
You might also like
The redox switch that regulates molecular chaperones
(2015)
Journal Article
Downloadable Citations
About UWE Bristol Research Repository
Administrator e-mail: repository@uwe.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2024
Advanced Search