Abstract
Purpose: To evaluate and compare the deliverability of ‘sawtooth’ proton arc therapy (PAT) plans relative to static intensity modulated proton therapy (IMPT) at a cyclotron-based clinical facility.
Methods: The delivery of single and dual arc Sawtooth PAT plans for an abdominal CT phantom and multiple clinical cases of brain, head and neck (H&N) and base of skull (BoS) targets was emulated under the step-and-shoot and continuous PAT delivery regimes and compared to that of a corresponding static IMPT plan.
Results: Continuous PAT delivery increased the time associated with beam delivery and gantry movement in single/dual PAT plans by 4.86/7.34 min (brain), 7.51/12.40 min (BoS) and 6.59/10.57 min (H&N) on average relative to static IMPT. Step-and-shoot PAT increased this delivery time further by 4.79 min on average as the delivery was limited by gantry motion.
Conclusions: The emulator can approximately model clinical sawtooth PAT delivery but requires experimental validation. No clear benefit was observed regarding beam-on time for sawtooth PAT relative to static IMPT.
Journal Article Type | Article |
---|---|
Acceptance Date | Sep 19, 2024 |
Online Publication Date | Sep 27, 2024 |
Publication Date | Oct 1, 2024 |
Deposit Date | Oct 14, 2024 |
Publicly Available Date | Oct 14, 2024 |
Journal | Cancers |
Electronic ISSN | 2072-6694 |
Publisher | MDPI |
Peer Reviewed | Peer Reviewed |
Volume | 16 |
Issue | 19 |
Article Number | 3315 |
DOI | https://doi.org/10.3390/cancers16193315 |
Public URL | https://uwe-repository.worktribe.com/output/13285107 |
Files
Emulating the delivery of sawtooth proton arc therapy plans on a cyclotron-based proton beam therapy system
(823 Kb)
PDF
Licence
http://creativecommons.org/licenses/by/4.0/
Publisher Licence URL
http://creativecommons.org/licenses/by/4.0/
You might also like
Terminology, recording, reporting for ultra-high dose rates: ESTRO physics of FLASH workshop update
(2024)
Presentation / Conference Contribution
How precisely to deliver pencil beam scanned proton FLASH? Robustness of dose rate to AAPM TG224
(2024)
Presentation / Conference Contribution
Downloadable Citations
About UWE Bristol Research Repository
Administrator e-mail: repository@uwe.ac.uk
This application uses the following open-source libraries:
SheetJS Community Edition
Apache License Version 2.0 (http://www.apache.org/licenses/)
PDF.js
Apache License Version 2.0 (http://www.apache.org/licenses/)
Font Awesome
SIL OFL 1.1 (http://scripts.sil.org/OFL)
MIT License (http://opensource.org/licenses/mit-license.html)
CC BY 3.0 ( http://creativecommons.org/licenses/by/3.0/)
Powered by Worktribe © 2025
Advanced Search