Skip to main content

Research Repository

Advanced Search

Outputs (60)

The redox behaviour of diazepam (Valium®) using a disposable screen-printed sensor and its determination in drinks using a novel adsorptive stripping voltammetric assay (2013)
Journal Article

In this study we investigated the possibility of applying disposable electrochemical screen-printed carbon sensors for the rapid identification and quantitative determination of diazepam in beverages. This was achieved utilising a previously unreport... Read More about The redox behaviour of diazepam (Valium®) using a disposable screen-printed sensor and its determination in drinks using a novel adsorptive stripping voltammetric assay.

The chronoamperometric and voltammetric behaviour of glutathione at screen-printed carbon micro-band electrodes modified with cobalt phthalocyanine (2012)
Journal Article

Screen-printed carbon electrodes (SPCEs) incorporating the electrocatalyst cobalt phthalocyanine (CoPC) have been successfully used for the manufacture of microband electrodes for the determination of reduced glutathione (GSH). Initially investigati... Read More about The chronoamperometric and voltammetric behaviour of glutathione at screen-printed carbon micro-band electrodes modified with cobalt phthalocyanine.

Novel electrode reactions of diazepam, flunitrazepam and lorazepam and their exploitation in a new redox mode LC-DED assay for serum (2012)
Journal Article

Previously unreported voltammetric redox behaviour was identified for flunitrazepam, lorazepam and diazepam at a glassy carbon electrode. This was successfully exploited for their determination in serum by high performance liquid chromatography dual... Read More about Novel electrode reactions of diazepam, flunitrazepam and lorazepam and their exploitation in a new redox mode LC-DED assay for serum.

Determination of catecholamines in urine using hydrophilic interaction chromatography with electrochemical detection (2011)
Journal Article

The determination of catecholamines in urine was investigated using hydrophilic interaction chromatography (HILIC) as an alternative to the commonly used reversed-phase (RP) method. A number of different approaches were explored, including per-aqueou... Read More about Determination of catecholamines in urine using hydrophilic interaction chromatography with electrochemical detection.

The voltammetric behaviour of lead at a microband screen-printed carbon electrode and its determination in acetate leachates from glazed ceramic plates (2011)
Journal Article

Microband screen-printed carbon electrodes (μBSPCEs) without further modification have been investigated as disposable sensors for the measurement of lead in acetate leachates from ceramic glazed plates. Cyclic voltammetry was employed to elucidate t... Read More about The voltammetric behaviour of lead at a microband screen-printed carbon electrode and its determination in acetate leachates from glazed ceramic plates.

A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides (2011)
Journal Article

Organophosphate pesticides present serious risks to human and environmental health. A rapid reliable, economical and portable analytical system will be of great benefit in the detection and prevention of contamination. A biosensor array based on six... Read More about A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides.

A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture (2011)
Journal Article

Microband biosensors, screen-printed from a water-based carbon ink containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, were used to monitor glucose levels continuously in buffer and culture medium. Five biosensors were o... Read More about A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture.

Voltammetric behavior of DNA and its derivatives using screen printed carbon electrodes and its possible application in genotoxicity screening (2010)
Journal Article

The aim of the current work was to characterize the electrochemical behavior of DNA and its derivatives using screen printed carbon electrodes (SPCEs). Differential pulse voltammetry (DPV) was carried out on guanine, adenine, 8-oxyguanine, 8-deoxygau... Read More about Voltammetric behavior of DNA and its derivatives using screen printed carbon electrodes and its possible application in genotoxicity screening.

Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+ (2010)
Journal Article

A biosensor for the measurement of lactate in serum has been developed, which is based on a screen-printed carbon electrode, modified with Meldola's Blue-Reinecke Salt (MBRS-SPCE), coated with the enzyme lactate dehydrogenase NAD+ dependent (from Por... Read More about Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+.