Chapter 23 Screen-printed electrochemical (bio)sensors in biomedical, environmental and industrial applications (2007)
Journal Article
Hart, J. P., Crew, A., Crouch, E., Honeychurch, K. C., & Pemberton, R. (2007). Chapter 23 Screen-printed electrochemical (bio)sensors in biomedical, environmental and industrial applications. https://doi.org/10.1016/S0166-526X%2806%2949023-1

This chapter describes a number of approaches for the fabrication of prototype screen-printed electrochemical (bio) sensors together with selected applications in the areas of biomedical, environmental and industrial analyses. Novel methods of immobi... Read More about Chapter 23 Screen-printed electrochemical (bio)sensors in biomedical, environmental and industrial applications.

Voltammetric behaviour of p-nitrophenol and its trace determination in human urine by liquid chromatography with a dual reductive mode electrochemical detection system (2007)
Journal Article
Honeychurch, K. C., & Hart, J. P. (2007). Voltammetric behaviour of p-nitrophenol and its trace determination in human urine by liquid chromatography with a dual reductive mode electrochemical detection system. Electroanalysis, 19(21), 2176-2184. https://doi.org/10.1002/elan.200703989

The determination of trace p-nitrophenol (PNP) concentrations in human urine has been successfully achieved by high performance liquid chromatography dual electrode detection (LC-DED) in the reduction-reduction mode. Initial cyclic voltammetric studi... Read More about Voltammetric behaviour of p-nitrophenol and its trace determination in human urine by liquid chromatography with a dual reductive mode electrochemical detection system.

Voltammetric behavior of p-nitrophenol and its trace determination in human urine by liquid chromatography with a dual reductive mode electrochemical detection system (2007)
Journal Article
Honeychurch, K. C., & Hart, J. P. (2007). Voltammetric behavior of p-nitrophenol and its trace determination in human urine by liquid chromatography with a dual reductive mode electrochemical detection system. Electroanalysis, 19(21), 2176-2184. https://doi.org/10.1002/elan.200703989

The determination of trace p-nitrophenol (PNP) concentrations in human urine has been successfully achieved by high performance liquid chromatography dual electrode detection (LC-DED) in the reduction-reduction mode. Initial cyclic voltammetric studi... Read More about Voltammetric behavior of p-nitrophenol and its trace determination in human urine by liquid chromatography with a dual reductive mode electrochemical detection system.

Development of a novel electrochemical immuno-assay using a screen printed electrode for the determination of secretory immunoglobulin A in human sweat (2007)
Journal Article
Cowell, D. C., Crew, A. P., Alford, C., & Hart, J. P. (2007). Development of a novel electrochemical immuno-assay using a screen printed electrode for the determination of secretory immunoglobulin A in human sweat. Electrochimica Acta, 52(16), 5232-5237. https://doi.org/10.1016/j.electacta.2007.02.035

This paper reports on the steps involved in the development of a novel electrochemical immunoassay for secretory immunoglobulin A (sIgA) determinations in human sweat. This novel immunoassay involves an initial step whereby sweat sIgA is adsorbed ont... Read More about Development of a novel electrochemical immuno-assay using a screen printed electrode for the determination of secretory immunoglobulin A in human sweat.

Voltammetric behaviour of DNA bases at a screen-printed carbon electrode and its application to a simple and rapid voltammetric method for the determination of oxidative damage in double stranded DNA (2007)
Journal Article
O'Donovan, M. R., Honeychurch, K. C., & Hart, J. P. (2007). Voltammetric behaviour of DNA bases at a screen-printed carbon electrode and its application to a simple and rapid voltammetric method for the determination of oxidative damage in double stranded DNA. Biosensors and Bioelectronics, 22(9-10), 2057-2064. https://doi.org/10.1016/j.bios.2006.09.019

Screen-printed carbon electrodes (SPCEs) have been investigated as possible sensors to identify γ-irradiation induced oxidative damage in double stranded (ds) DNA. Studies were undertaken to explore the possibility of using both cyclic voltammetry an... Read More about Voltammetric behaviour of DNA bases at a screen-printed carbon electrode and its application to a simple and rapid voltammetric method for the determination of oxidative damage in double stranded DNA.

Selective and rapid biosensor integrated into a commercial hand-held instrument for the measurement of ammonium ion in sewage effluent (2006)
Journal Article
Hart, J. P., Serban, S., Jones, L. J., Biddle, N., Pittson, R., & Drago, G. A. (2006). Selective and rapid biosensor integrated into a commercial hand-held instrument for the measurement of ammonium ion in sewage effluent. Analytical Letters, 39(8), 1657-1667. https://doi.org/10.1080/00032710600713545

A disposable biosensor for ammonium ions in sewage effluent was developed and based on a screen-printed carbon electrode coated with the enzyme glutamate dehydrogenase, 2-oxoglutarate, and NADH. This rapid and selective amperometric biosensor is capa... Read More about Selective and rapid biosensor integrated into a commercial hand-held instrument for the measurement of ammonium ion in sewage effluent.

Studies towards the development of a screen-printed carbon electrochemical immunosensor array for mycotoxins: A sensor for aflatoxin B1 (2006)
Journal Article
Pemberton, R., Pittson, R., Biddle, N., Drago, G. A., & Hart, J. P. (2006). Studies towards the development of a screen-printed carbon electrochemical immunosensor array for mycotoxins: A sensor for aflatoxin B1. Analytical Letters, 39(8), 1573-1586. https://doi.org/10.1080/00032710600713289

Screen-printed carbon electrodes (SPCEs) bearing a surface-adsorbed antibody against aflatoxin B1 (AFB1) were used in a competitive immunoassay, based on competition of free analyte with a biotinylated aflatoxin B1 conjugate. Subsequent addition of s... Read More about Studies towards the development of a screen-printed carbon electrochemical immunosensor array for mycotoxins: A sensor for aflatoxin B1.

Voltammetric behavior of nitrazepam and its determination in serum using liquid chromatography with redox mode dual-electrode detection (2006)
Journal Article
Honeychurch, K. C., Smith, G. C., & Hart, J. P. (2006). Voltammetric behavior of nitrazepam and its determination in serum using liquid chromatography with redox mode dual-electrode detection. Analytical Chemistry, 78(2), 416-423. https://doi.org/10.1021/ac058035a

A method involving high-performance liquid chromatography with dual-electrode electrochemical detection in the redox mode (LC-DED) has been successfully developed for the determination of the benzodiazepine tranquilizer, nitrazepam, in serum. To eluc... Read More about Voltammetric behavior of nitrazepam and its determination in serum using liquid chromatography with redox mode dual-electrode detection.

Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase (2005)
Journal Article
Crouch, E., Cowell, D. C., Hoskins, S., Pittson, R. W., & Hart, J. P. (2005). Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase. Analytical Biochemistry, 347(1), 17-23. https://doi.org/10.1016/j.ab.2005.08.011

This paper describes the optimisation of a screen-printing water-based carbon ink containing cobalt phthalocyanine (CoPC) and glucose oxidase (GOD) for the fabrication of a glucose biosensor. To optimise the performance of the biosensor, the loadings... Read More about Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase.