Enhancing self-directed upper-limb (UL) exercise practice using GripAble gaming device and Lycra arm sleeve in people with stroke (PwS): An evaluative study (2023)
Presentation / Conference
Pearce, A., Ruiz Garate, V., Welsby, J., Caleb-Solly, P., & Kumar, P. (2023, December). Enhancing self-directed upper-limb (UL) exercise practice using GripAble gaming device and Lycra arm sleeve in people with stroke (PwS): An evaluative study. Poster presented at UK Stroke Forum, Birmingham

Background: The national clinical guidelines recommend repetitive task training to enhance UL rehabilitation in PwS. GripAble™ (a self-directed exergaming device) has shown to increase repetitive practice in PwS. Previous studies have shown that a Ly... Read More about Enhancing self-directed upper-limb (UL) exercise practice using GripAble gaming device and Lycra arm sleeve in people with stroke (PwS): An evaluative study.

Accelerometers-embedded Lycra sleeves to test wear compliance and upper limb activity in people with stroke: A feasibility study (2021)
Journal Article
Kumar, P., Brodie, S., Molton, J., O'Reilly, R., Steele, J., Pearce, A., …Caleb-Solly, P. (2023). Accelerometers-embedded Lycra sleeves to test wear compliance and upper limb activity in people with stroke: A feasibility study. Journal of Prosthetics and Orthotics, 35(2), 122-128. https://doi.org/10.1097/JPO.0000000000000406

Introduction To establish a possible effect of Lycra sleeves, accurate recording of wear time is critical. The aim of this study was to test whether an accelerometer-embedded Lycra sleeve can measure wear compliance and record upper-limb (UL) movemen... Read More about Accelerometers-embedded Lycra sleeves to test wear compliance and upper limb activity in people with stroke: A feasibility study.

Accelerometers - Embedded lycra sleeves to test wear compliance and upper limb activity in people with stroke: a feasibility study - UK Stroke Forum 2021 (2021)
Presentation / Conference
Kumar, P., Leake, J., Brodie, S., Molton, J., O'Reilly, R., Pearce, A., …Caleb-Solly, P. (2021, November). Accelerometers - Embedded lycra sleeves to test wear compliance and upper limb activity in people with stroke: a feasibility study - UK Stroke Forum 2021. Presented at UK Stroke Forum Conference, 2021, Telford, UK and online

Background: To establish a possible effect of Lycra sleeves, accurate recording of wear time is critical. The aim of this study was to test whether an accelerometer-embedded Lycra sleeve can measure wear compliance and record upper limb (UL) movement... Read More about Accelerometers - Embedded lycra sleeves to test wear compliance and upper limb activity in people with stroke: a feasibility study - UK Stroke Forum 2021.

Lycra sleeves with embedded-Accelerometers to test wear compliance and upper limb activity in people with stroke: A feasibility study  (2021)
Presentation / Conference
Kumar, P., Leake, J., Brodie, S., Molton, J., O'Reilly, R., Pearce, A., …Caleb-Solly, P. (2021, October). Lycra sleeves with embedded-Accelerometers to test wear compliance and upper limb activity in people with stroke: A feasibility study . Poster presented at CAHPR Oxfordshire and CAHPR Southwest Conference 2021, Online

Background: To establish a possible effect of Lycra sleeves, accurate recording of wear time is critical. Aim: To test whether an accelerometer-embedded Lycra sleeve can measure wear compliance and record upper-limb (UL) movements/activity in people... Read More about Lycra sleeves with embedded-Accelerometers to test wear compliance and upper limb activity in people with stroke: A feasibility study .