Skip to main content

Research Repository

Advanced Search

All Outputs (5)

The chronoamperometric and voltammetric behaviour of glutathione at screen-printed carbon micro-band electrodes modified with cobalt phthalocyanine (2012)
Journal Article
Honeychurch, K. C., & Hart, J. P. (2012). The chronoamperometric and voltammetric behaviour of glutathione at screen-printed carbon micro-band electrodes modified with cobalt phthalocyanine. Advances in Analytical Chemistry, 2(5), 46-52. https://doi.org/10.5923/j.aac.20120205.01

Screen-printed carbon electrodes (SPCEs) incorporating the electrocatalyst cobalt phthalocyanine (CoPC) have been successfully used for the manufacture of microband electrodes for the determination of reduced glutathione (GSH). Initially investigati... Read More about The chronoamperometric and voltammetric behaviour of glutathione at screen-printed carbon micro-band electrodes modified with cobalt phthalocyanine.

Voltammetric behaviour of lead at a microband screen-printed carbon electrode and its trace determination in plants by stripping voltammetry (2012)
Presentation / Conference
Phillips, R., Honeychurch, K. C., Crew, A. P., Davies, R., Willey, N., & Hart, J. P. (2012, September). Voltammetric behaviour of lead at a microband screen-printed carbon electrode and its trace determination in plants by stripping voltammetry. Poster presented at Electrochem 2012: Electrochemical Horizons, Trinity College, Dublin

Development of a sandwich format, amperometric screen-printed uric acid biosensor for urine analysis (2012)
Journal Article
Kanyong, P., Pemberton, R., Jackson, S. K., & Hart, J. P. (2012). Development of a sandwich format, amperometric screen-printed uric acid biosensor for urine analysis. Analytical Biochemistry, 428(1), 39-43. https://doi.org/10.1016/j.ab.2012.05.027

A screen-printed carbon electrode (SPCE) incorporating the electrocatalyst cobalt phthalocyanine (CoPC), fabricated using a water-based ink formulation, has been investigated as the base transducer for a uric acid biosensor. A sandwich biosensor was... Read More about Development of a sandwich format, amperometric screen-printed uric acid biosensor for urine analysis.

Redox mechanisms of rohypnol and mogadon and their exploitation in an assay using dual electrode ECD following HPLC (2012)
Presentation / Conference
Honeychurch, K. C., Li, H., Pericleous, S., Antoniou, M., Abed, A., & Hart, J. P. (2012, June). Redox mechanisms of rohypnol and mogadon and their exploitation in an assay using dual electrode ECD following HPLC. Presented at Great Western Electrochemistry Meeting, University of Bath

Importance of the 1,4-benzodiazepine class of drugs Cyclic voltammetric behaviour of Flunitrazepam (Rohypnol), and Nitrazepam (Mogadon) Possible mechanism for their voltammetric behaviour Optimisation of Liquid Chromatographic Separation and... Read More about Redox mechanisms of rohypnol and mogadon and their exploitation in an assay using dual electrode ECD following HPLC.

Novel electrode reactions of diazepam, flunitrazepam and lorazepam and their exploitation in a new redox mode LC-DED assay for serum (2012)
Journal Article
Honeychurch, K. C., Chong, A. T., Elamin, K., & Hart, J. P. (2012). Novel electrode reactions of diazepam, flunitrazepam and lorazepam and their exploitation in a new redox mode LC-DED assay for serum. Analytical Methods, 4(1), 132-140. https://doi.org/10.1039/c1ay05419h

Previously unreported voltammetric redox behaviour was identified for flunitrazepam, lorazepam and diazepam at a glassy carbon electrode. This was successfully exploited for their determination in serum by high performance liquid chromatography dual... Read More about Novel electrode reactions of diazepam, flunitrazepam and lorazepam and their exploitation in a new redox mode LC-DED assay for serum.