Skip to main content

Research Repository

Advanced Search

All Outputs (7)

Development of an amperometric, screen-printed, single-enzyme phosphate ion biosensor and its application to the analysis of biomedical and environmental samples (2011)
Journal Article
Jenkins, A. T., Gilbert, L., Browning, S., & Hart, J. P. (2011). Development of an amperometric, screen-printed, single-enzyme phosphate ion biosensor and its application to the analysis of biomedical and environmental samples. Sensors and Actuators B: Chemical, 160(1), 1322-1327. https://doi.org/10.1016/j.snb.2011.09.069

An amperometric phosphate biosensor, based on a cobalt phthalocyanine screen-printed carbon electrode (CoPC-SPCE) is described. The immobilisation of the enzyme pyruvate oxidase (PyOd) was investigated using pre-formed cellulose acetate/cellulose nit... Read More about Development of an amperometric, screen-printed, single-enzyme phosphate ion biosensor and its application to the analysis of biomedical and environmental samples.

Determination of catecholamines in urine using hydrophilic interaction chromatography with electrochemical detection (2011)
Journal Article
Kumar, A., Hart, J. P., & McCalley, D. V. (2011). Determination of catecholamines in urine using hydrophilic interaction chromatography with electrochemical detection. Journal of Chromatography A, 1218(25), 3854-3861. https://doi.org/10.1016/j.chroma.2011.04.034

The determination of catecholamines in urine was investigated using hydrophilic interaction chromatography (HILIC) as an alternative to the commonly used reversed-phase (RP) method. A number of different approaches were explored, including per-aqueou... Read More about Determination of catecholamines in urine using hydrophilic interaction chromatography with electrochemical detection.

The voltammetric behaviour of lead at a microband screen-printed carbon electrode and its determination in acetate leachates from glazed ceramic plates (2011)
Journal Article
Honeychurch, K. C., Al-Berezanchi, S., & Hart, J. P. (2011). The voltammetric behaviour of lead at a microband screen-printed carbon electrode and its determination in acetate leachates from glazed ceramic plates. Talanta, 84(3), 717-723. https://doi.org/10.1016/j.talanta.2011.01.073

Microband screen-printed carbon electrodes (μBSPCEs) without further modification have been investigated as disposable sensors for the measurement of lead in acetate leachates from ceramic glazed plates. Cyclic voltammetry was employed to elucidate t... Read More about The voltammetric behaviour of lead at a microband screen-printed carbon electrode and its determination in acetate leachates from glazed ceramic plates.

A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides (2011)
Journal Article
Crew, A. P., Lonsdale, D., Byrd, N., Pittson, R., & Hart, J. P. (2011). A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides. Biosensors and Bioelectronics, 26(6), 2847-2851. https://doi.org/10.1016/j.bios.2010.11.018

Organophosphate pesticides present serious risks to human and environmental health. A rapid reliable, economical and portable analytical system will be of great benefit in the detection and prevention of contamination. A biosensor array based on six... Read More about A screen-printed, amperometric biosensor array incorporated into a novel automated system for the simultaneous determination of organophosphate pesticides.

A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture (2011)
Journal Article
Xu, J., Pemberton, R., Pittson, R., Drago, G. A., Griffiths, J., Jackson, S. K., & Hart, J. P. (2011). A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture. Biosensors and Bioelectronics, 26(5), 2448-2453. https://doi.org/10.1016/j.bios.2010.10.030

Microband biosensors, screen-printed from a water-based carbon ink containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, were used to monitor glucose levels continuously in buffer and culture medium. Five biosensors were o... Read More about A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture.

A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture (2011)
Journal Article
Pemberton, R., Xu, J., Pittson, R., Drago, G., Griffiths, J., Jackson, S. K., & Hart, J. P. (2011). A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture. Biosensors and Bioelectronics, 26(5), 2448-2453. https://doi.org/10.1016/j.bios.2010.10.030

#Microband biosensors, screen-printed from a water-based carbon ink containing cobalt phthalocyanine redox mediator and glucose oxidase (GOD) enzyme, were used to monitor glucose levels continuously in buffer and culture medium. Five biosensors were... Read More about A screen-printed microband glucose biosensor system for real-time monitoring of toxicity in cell culture.