Skip to main content

Research Repository

Advanced Search

All Outputs (6)

Voltammetric behavior of DNA and its derivatives using screen printed carbon electrodes and its possible application in genotoxicity screening (2010)
Journal Article
Rawson, F. J., Jackson, S. K., & Hart, J. P. (2010). Voltammetric behavior of DNA and its derivatives using screen printed carbon electrodes and its possible application in genotoxicity screening. Analytical Letters, 43(10-11), 1790-1800. https://doi.org/10.1080/00032711003653908

The aim of the current work was to characterize the electrochemical behavior of DNA and its derivatives using screen printed carbon electrodes (SPCEs). Differential pulse voltammetry (DPV) was carried out on guanine, adenine, 8-oxyguanine, 8-deoxygau... Read More about Voltammetric behavior of DNA and its derivatives using screen printed carbon electrodes and its possible application in genotoxicity screening.

Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+ (2010)
Journal Article
Piano, M., Serban, S., Pittson, R., Drago, G. A., & Hart, J. P. (2010). Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+. Talanta, 82(1), 34-37. https://doi.org/10.1016/j.talanta.2010.03.051

A biosensor for the measurement of lactate in serum has been developed, which is based on a screen-printed carbon electrode, modified with Meldola's Blue-Reinecke Salt (MBRS-SPCE), coated with the enzyme lactate dehydrogenase NAD+ dependent (from Por... Read More about Amperometric lactate biosensor for flow injection analysis based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt, coated with lactate dehydrogenase and NAD+.

Electrocatalytic behaviour of citric acid at a cobalt phthalocyanine- modified screen-printed carbon electrode and its application in pharmaceutical and food analysis (2010)
Journal Article
Honeychurch, K. C., Gilbert, L., & Hart, J. P. (2010). Electrocatalytic behaviour of citric acid at a cobalt phthalocyanine- modified screen-printed carbon electrode and its application in pharmaceutical and food analysis. Analytical and Bioanalytical Chemistry, 396(8), 3103-3111. https://doi.org/10.1007/s00216-010-3534-x

Cobalt phthalocyanine-modified screen-printed carbon electrodes (CoPC-SPCEs) have been investigated as disposable sensors for the measurement of citric acid. The analyte was found to undergo an electrocatalytic oxidation process involving the Co2+/Co... Read More about Electrocatalytic behaviour of citric acid at a cobalt phthalocyanine- modified screen-printed carbon electrode and its application in pharmaceutical and food analysis.

Application of screen-printed microband biosensors incorporated with cells to monitor metabolic effects of potential environmental toxins (2010)
Journal Article
Pemberton, R., Rawson, F. J., Xu, J., Pittson, R., Drago, G. A., Griffiths, J., …Hart, J. P. (2010). Application of screen-printed microband biosensors incorporated with cells to monitor metabolic effects of potential environmental toxins. Microchimica Acta, 170(3), 321-330. https://doi.org/10.1007/s00604-010-0326-0

Microband biosensors were fabricated from a screen-printed water-based carbon ink containing cobalt phthalocyanine redox mediator and glucose oxidase or lactate oxidase enzyme. The microbiosensors were characterised for their ability to monitor ferro... Read More about Application of screen-printed microband biosensors incorporated with cells to monitor metabolic effects of potential environmental toxins.

Studies towards an amperometric phosphate ion biosensor for urine and water analysis (2010)
Journal Article
Jenkins, A. T., Gilbert, L., Browning, S., & Hart, J. P. (2010). Studies towards an amperometric phosphate ion biosensor for urine and water analysis. Microchimica Acta, 170(3), 331-336. https://doi.org/10.1007/s00604-010-0316-2

An amperometric biosensor for phosphate ion is described that is based on a cobalt phthalocyanine modified screen-printed carbon electrode (CoPC-SPCE). The biosensor operation is based on the enzyme pyruvate oxidase (PyOd) which catalyses the oxidati... Read More about Studies towards an amperometric phosphate ion biosensor for urine and water analysis.

A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose (2010)
Journal Article
Piano, M., Serban, S., Biddle, N., Pittson, R., Drago, G. A., & Hart, J. P. (2010). A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose. Analytical Biochemistry, 396(2), 269-274. https://doi.org/10.1016/j.ab.2009.09.028

A biosensor for the measurement of glucose in serum has been developed, based on a screen-printed carbon electrode modified with Meldola's Blue-Reinecke salt, coated with the enzyme glucose dehydrogenase (from Bacillus sp.), and nicotinamide adenine... Read More about A flow injection system, comprising a biosensor based on a screen-printed carbon electrode containing Meldola's Blue-Reinecke salt coated with glucose dehydrogenase, for the measurement of glucose.