Skip to main content

Research Repository

Advanced Search

All Outputs (13)

Development of a novel functional electrical stimulation system for hand rehabilitation using feedback control (2016)
Journal Article
Ruppel, M., Seel, T., & Dogramadzi, S. (2016). Development of a novel functional electrical stimulation system for hand rehabilitation using feedback control. Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2016-July, 1135-1139. https://doi.org/10.1109/BIOROB.2016.7523784

© 2016 IEEE. Worldwide stroke is a leading cause for disability and the demand for rehabilitation devices and everyday life assistance is still high. To address this demand, we consider a combination of Functional Electrical Stimulation (FES) of the... Read More about Development of a novel functional electrical stimulation system for hand rehabilitation using feedback control.

An assistive robot to support dressing-strategies for planning and error handling (2016)
Journal Article
Chance, G., Chance, G., Camilleri, A., Winstone, B., Caleb-Solly, P., & Dogramadzi, S. (2016). An assistive robot to support dressing-strategies for planning and error handling. Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2016-July, 774-780. https://doi.org/10.1109/BIOROB.2016.7523721

© 2016 IEEE. Assistive robots are emerging to address a social need due to changing demographic trends such as an ageing population. The main emphasis is to offer independence to those in need and to fill a potential labour gap in response to the inc... Read More about An assistive robot to support dressing-strategies for planning and error handling.

Intra-operative 3D imaging system for robot-assisted fracture manipulation (2015)
Journal Article
Dagnino, G., Georgilas, I., Tarassoli, P., Atkins, R., & Dogramadzi, S. (2015). Intra-operative 3D imaging system for robot-assisted fracture manipulation. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2015-November, 9-12. https://doi.org/10.1109/EMBC.2015.7318248

© 2015 IEEE. Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and low... Read More about Intra-operative 3D imaging system for robot-assisted fracture manipulation.

Powered exoskeleton with palm degrees of freedom for hand rehabilitation (2015)
Journal Article
Richards, D. S., Georgilas, I., Dagnino, G., & Dogramadzi, S. (2015). Powered exoskeleton with palm degrees of freedom for hand rehabilitation. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2015-November, 4635-4638. https://doi.org/10.1109/EMBC.2015.7319427

© 2015 IEEE. Robotic rehabilitation is a currently underutilised field with the potential to allow huge cost savings within healthcare. Existing rehabilitation exoskeletons oversimplify the importance of movement of the hand while undertaking everyda... Read More about Powered exoskeleton with palm degrees of freedom for hand rehabilitation.

Preliminary analysis of force-torque measurements for robot-assisted fracture surgery (2015)
Journal Article
Georgilas, I., Dagnino, G., Tarassoli, P., Atkins, R., & Dogramadzi, S. (2015). Preliminary analysis of force-torque measurements for robot-assisted fracture surgery. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference, 2015-November, 4902-4905. https://doi.org/10.1109/EMBC.2015.7319491

© 2015 IEEE. Our group at Bristol Robotics Laboratory has been working on a new robotic system for fracture surgery that has been previously reported [1]. The robotic system is being developed for distal femur fractures and features a robot that mani... Read More about Preliminary analysis of force-torque measurements for robot-assisted fracture surgery.

Biomimetic tactile sensing capsule (2015)
Journal Article
Pipe, T., Winstone, B., Pipe, A. G., Melhuish, C., Dogramadzi, S., & Callaway, M. (2015). Biomimetic tactile sensing capsule. Lecture Notes in Artificial Intelligence, 9222, 113-122. https://doi.org/10.1007/978-3-319-22979-9_12

© Springer International Publishing Switzerland 2015. Here we present a tactile sensing capsule endoscopy system. Whilst current capsule endoscopy utilises cameras to diagnose lesions on the surface of the gastrointestinal tract lumen, this proposal... Read More about Biomimetic tactile sensing capsule.

A novel bio-inspired tactile tumour detection concept for capsule endoscopy (2014)
Journal Article
Pipe, T., Winstone, B., Melhuish, C., Dogramadzi, S., Pipe, A. G., & Callaway, M. (2014). A novel bio-inspired tactile tumour detection concept for capsule endoscopy. Lecture Notes in Artificial Intelligence, 8608 LNAI, 442-445. https://doi.org/10.1007/978-3-319-09435-9_56

Examination of the gastrointestinal(GI) tract has traditionally been performed using endoscopy tools that allow a surgeon to see the inside of the lining of the digestive tract. Endoscopes are rigid or flexible tubes that use fibre-optics or cameras... Read More about A novel bio-inspired tactile tumour detection concept for capsule endoscopy.

Towards a variable compliance hydrostatic skeleton inspired gripper (2012)
Journal Article
Zheng, Y., Giannaccini, M. E., Dogramadzi, S., & Pipe, A. G. (2012). Towards a variable compliance hydrostatic skeleton inspired gripper. Proceedings of the ... IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics. IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 246-251. https://doi.org/10.1109/BioRob.2012.6290885

Variable compliance is a subject of great interest in the robotics community, particularly in the area of HumanRobot interaction. In this work, variable compliance is achieved in a novel grasping device inspired by the hydrostatic skeletons of invert... Read More about Towards a variable compliance hydrostatic skeleton inspired gripper.

Towards an anthropomorphic design of minimally invasive instrumentation for soft tissue robotic surgery (2012)
Journal Article
Pipe, T., Tzemanaki, A., Dogramadzi, S., Pipe, A. G., & Melhuish, C. (2012). Towards an anthropomorphic design of minimally invasive instrumentation for soft tissue robotic surgery. Lecture Notes in Artificial Intelligence, 7429 LNAI, 455-456. https://doi.org/10.1007/978-3-642-32527-4_56

Minimally invasive procedures, such as laparoscopy, have significantly decreased blood loss, postoperative morbidity and length of hospital stay. Robot-assisted Minimally Invasive Surgery (MIS) has offered refined accuracy and more ergonomic instrume... Read More about Towards an anthropomorphic design of minimally invasive instrumentation for soft tissue robotic surgery.

Towards tactile sensing applied to underwater autonomous vehicles for near shore survey and de-mining (2012)
Journal Article
Rooney, T., Pipe, A. G., Dogramadzi, S., & Pearson, M. (2012). Towards tactile sensing applied to underwater autonomous vehicles for near shore survey and de-mining. Lecture Notes in Artificial Intelligence, 7429 LNAI, 463-464. https://doi.org/10.1007/978-3-642-32527-4_60

Artificial tactile whisker sensors demonstrate an approach to localisation [1] that is robust to harsh environmental disturbances, endowing autonomous systems with the ability to operate effectively in confined, noisy and visually occluded spaces, su... Read More about Towards tactile sensing applied to underwater autonomous vehicles for near shore survey and de-mining.

Semi-automatic percutaneous reduction of intra-articular joint fractures - An initial analysis (2012)
Journal Article
Raabe, D., Dogramadzi, S., & Atkins, R. (2012). Semi-automatic percutaneous reduction of intra-articular joint fractures - An initial analysis. IEEE International Conference on Robotics and Automation, 2679-2684. https://doi.org/10.1109/ICRA.2012.6225076

Robot-assisted orthopaedic surgery has proved to provide better outcomes over conventional surgery in terms of improved spatial accuracy and more reliable and repeatable results. We present a novel use of robots in orthopaedic surgery - precise anato... Read More about Semi-automatic percutaneous reduction of intra-articular joint fractures - An initial analysis.

Development of a novel robotic system for hand rehabilitation (2011)
Journal Article
Raabe, D., Tzemanaki, A., & Dogramadzi, S. (2011). Development of a novel robotic system for hand rehabilitation. https://doi.org/10.1109/CBMS.2011.5999150

Rehabilitation Robotics involves the use of robotic systems as an enabling technology for people with kinetic problems, in order to help them recover from a physical trauma. This paper presents the investigation of a robotic system for stroke and pos... Read More about Development of a novel robotic system for hand rehabilitation.

Occupancy grid-based SLAM using a mobile robot with a ring of eight sonar transducers (2011)
Journal Article
Terzakis, G., & Dogramadzi, S. (2011). Occupancy grid-based SLAM using a mobile robot with a ring of eight sonar transducers. Lecture Notes in Artificial Intelligence, 6856 LNAI, 402-403. https://doi.org/10.1007/978-3-642-23232-9_48

The degree of accuracy by which a mobile robot can estimate the properties of its surrounding environment, and the ability to successfully navigate throughout the explored space are the main factors that may well determine its autonomy and efficiency... Read More about Occupancy grid-based SLAM using a mobile robot with a ring of eight sonar transducers.