Skip to main content

Research Repository

Advanced Search

All Outputs (3)

Design, novel quality check and experimental test of an original variable length stepped scarf repair scheme (2021)
Journal Article
Damghani, M., Bolanos, S., Chahar, A., Matthews, J., Atkinson, G. A., Murphy, A., & Edwards, T. (2022). Design, novel quality check and experimental test of an original variable length stepped scarf repair scheme. Composites Part B: Engineering, 230, Article 109542. https://doi.org/10.1016/j.compositesb.2021.109542

The performance of well-established stepped scarf repair schemes for highly loaded composite structures has been studied in previous works. However, none of the proposed repair schemes appear to minimise healthy material removal. Thus, this paper pro... Read More about Design, novel quality check and experimental test of an original variable length stepped scarf repair scheme.

Detection of barely visible impact damage in polymeric laminated composites using a biomimetic tactile whisker (2021)
Journal Article
Fotouhi, S., Khayatzadeh, S., Pui, W. X., Damghani, M., Bodaghi, M., & Fotouhi, M. (2021). Detection of barely visible impact damage in polymeric laminated composites using a biomimetic tactile whisker. Polymers, 13(20), Article 3587. https://doi.org/10.3390/polym13203587

This is a novel investigation on the possibility of detecting barely visible impact damage (BVID) in composite materials by whisking across the surface via tactile whisker sensors that resemble rats' whiskers. A series of drop tower low-velocity impa... Read More about Detection of barely visible impact damage in polymeric laminated composites using a biomimetic tactile whisker.

Using laminate hybridisation (CFRP-GFRP) and shaped CFRP plies to increase plate post-buckling strain to failure under shear loading (2021)
Journal Article
Damghani, M., Wallis, C., Bakunowicz, J., & Murphy, A. (2021). Using laminate hybridisation (CFRP-GFRP) and shaped CFRP plies to increase plate post-buckling strain to failure under shear loading. Thin-Walled Structures, 162, Article 107543. https://doi.org/10.1016/j.tws.2021.107543

Previous works have established the response and failure behaviour of hybrid (CFRP-GFRP) laminates when subjected to a wide range of destabilising loads. However, to date no works have quantified the influence of selective laminate shapes and hybridi... Read More about Using laminate hybridisation (CFRP-GFRP) and shaped CFRP plies to increase plate post-buckling strain to failure under shear loading.