Voltammetric behaviour of 2,6-dinitrotoluene at a screen-printed carbon electrode and its possible redox mechanisms
(2002)
Presentation / Conference
Honeychurch, K. C., Hart, J. P., Pritchard, P., Hawkins, S., & Ratcliffe, N. M. (2002, December). Voltammetric behaviour of 2,6-dinitrotoluene at a screen-printed carbon electrode and its possible redox mechanisms. Poster presented at Electrochem 2002, Preston, UK
All Outputs (7)
The stability of the biological components within a screen printed ammonium biosensor (2002)
Presentation / Conference
Shaw, E., Steele, D., Pemberton, R., Honeychurch, K. C., Pittson, R., Hart, J. P., & Drago, G. A. (2002, December). The stability of the biological components within a screen printed ammonium biosensor. Poster presented at Colorado Protein Stability Conference 2002, Colorado, USA
Molecularly imprinted polymers as recognition elements in screen-printed carbon electrodes (2002)
Presentation / Conference
Kirsch, N., Honeychurch, K. C., Hart, J. P., & Whitcombe, M. J. (2002, September). Molecularly imprinted polymers as recognition elements in screen-printed carbon electrodes. Poster presented at MIP 2002, Montpellier, France
Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode (2002)
Journal Article
Honeychurch, K. C., Hawkins, D. M., Hart, J. P., & Cowell, D. C. (2002). Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode. Talanta, 57(3), 565-574. https://doi.org/10.1016/S0039-9140%2802%2900060-7Screen-printed carbon electrodes (SPCEs), without chemical modification, have been investigated as disposable sensors for the measurement of trace levels of Cu2+. Cyclic voltammetry was employed to elucidate the electrochemical behaviour of Cu2+ at t... Read More about Voltammetric behaviour and trace determination of copper at a mercury-free screen-printed carbon electrode.
Electrochemical behaviour of 2,6-dinitrotoluene at a screen-printed sensor and its possible application in occupational hygiene and environmental studies (2002)
Presentation / Conference
Honeychurch, K. C., Hart, J. P., Pritchard, P., Hawkins, S., & Ratcliffe, N. M. (2002, May). Electrochemical behaviour of 2,6-dinitrotoluene at a screen-printed sensor and its possible application in occupational hygiene and environmental studies. Poster presented at Biosensors 2002, Kyoto, Japan
Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode (2002)
Journal Article
Arrigan, D. W., Cowell, D. C., Hart, J. P., Honeychurch, K. C., Honeychurch, K. C., Hawkins, D. M., …Cowell, D. C. (2002). Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode. Electroanalysis, 14(3), 177-185. https://doi.org/10.1002/1521-4109%28200202%2914%3A3%3C177%3A%3AAID-ELAN177%3E3.0.CO%3B2-VScreen-printed carbon electrodes (SPCEs) have been evaluated for the anodic stripping voltammetric determination of cadmium using open circuit accumulation facilitated by two different calixarenes: a novel thiolated calixarene, calixarene (I), (5,11,... Read More about Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode.
Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode (2002)
Journal Article
Honeychurch, K. C., Hart, J. P., Cowell, D. C., & Arrigan, D. W. (2002). Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode. Electroanalysis, 14(3), 177-185. https://doi.org/10.1002/1521-4109%28200202%2914%3A3%3C177%3A%3AAID-ELAN177%3E3.0.CO%3B2-VScreen-printed carbon electrodes (SPCEs) have been evaluated for the anodic stripping voltammetric determination of cadmium using open circuit accumulation facilitated by two different calixarenes: a novel thiolated calixarene, calixarene (I), (5,11,... Read More about Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode.