Skip to main content

Research Repository

Advanced Search

All Outputs (7)

Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs (2001)
Journal Article
McCalley, D. V., Luxton, R. W., Bird, D. J., Hart, J. P., Kirsch, N., Kirsch, N., …McCalley, D. V. (2001). Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs. Analyst, 126(11), 1936-1941. https://doi.org/10.1039/b108008n

This paper describes the fabrication of a sensor for 1-hydroxypyrene (1-OHP) based on a screen-printed carbon electrode (SPCE) modified with a molecularly imprinted polymer (MIP); 1-OHP was chosen as a model metabolite of polyaromatic hydrocarbons (P... Read More about Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs.

Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry (2001)
Journal Article
Arrigan, D. W., Cowell, D. C., Hart, J. P., Honeychurch, K. C., Honeychurch, K. C., Hart, J. P., …Arrigan, D. W. (2001). Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry. Sensors and Actuators B: Chemical, 77(3), 642-652. https://doi.org/10.1016/S0925-4005%2801%2900778-X

Screen-printed carbon electrodes (SPCEs) have been modified with two different calixarenes; a novel thiolated calixarene (5,11,17,23,tetra-tert-butyl-25,26,27,28-tetrakis(2-mercaptoethoxy)- calix[4]arene), and the commercially available 25,26,27,28-t... Read More about Voltammetric studies of lead at calixarene modified screen-printed carbon electrodes and its trace determination in water by stripping voltammetry.

Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry (2001)
Journal Article
Honeychurch, K. C., Hart, J. P., & Cowell, D. C. (2001). Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry. Analytica Chimica Acta, 431(1), 89-99. https://doi.org/10.1016/S0003-2670%2800%2901294-0

A method for the trace determination of Pb2+, using a disposable 1-(2-pyridylazo)-2-naphthol (PAN) drop-coated modified screen-printed carbon electrode (PAN-SPCE), has been developed. Lead ions (Pb2+) are accumulated from ammonia buffer, on the PAN-S... Read More about Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry.

Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry (2001)
Journal Article
Honeychurch, K. C., Hart, J. P., & Cowell, D. C. (2001). Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry. Analytica Chimica Acta, 431(1), 89-99. https://doi.org/10.1016/S0003-2670%2800%2901294-0

A method for the trace determination of Pb2+, using a disposable 1-(2-pyridylazo)-2-naphthol (PAN) drop-coated modified screen-printed carbon electrode (PAN-SPCE), has been developed. Lead ions (Pb2+) are accumulated from ammonia buffer, on the PAN-S... Read More about Voltammetric studies of lead at a 1-(2-pyridylazo)-2-naphthol modified screen-printed carbon electrode and its trace determination in water by stripping voltammetry.