Skip to main content

Research Repository

Advanced Search

Comparison of sequential and simultaneous breathing and pulse check by healthcare professionals during simulated scenarios

Soar, Jasmeet; Albarran, John; Moule, Pam; Gilchrist, Mollie

Authors

Jasmeet Soar

John Albarran

Pam Moule

Mollie Gilchrist



Abstract

Background: Basic life support guidelines for healthcare professionals recommend a sequential breathing and carotid pulse check allowing up to 10 s for each assessment. Life support providers are sometimes taught to do a simultaneous assessment of breathing and pulse check for up to 10 s. It is not clear whether this assessment improves diagnostic accuracy. Methods: We recruited 119 healthcare professionals. The SIM-Man™ was used to develop 10 simulated cases scenarios. To assess performance, 89 participants did 10 simultaneous assessments followed by 10 sequential assessments, and 29 participants did the assessment techniques in reverse order. The primary outcome of the study was the number of correct diagnoses made with each assessment method. Results: There were more correct diagnoses with a sequential assessment; 48.2% (569 out of 1180) compared to 33.5% (395 out of 1180) for the simultaneous method. Only 26.3% (n = 31) had more than five accurate diagnoses with a simultaneous assessment, compared to 44.1% (n = 52) for sequential assessments. Those performing sequential assessment achieved a median score of 5/10 correct diagnoses compared to a median score of 2.5/10 for the simultaneous method (Wilcoxon Z = -4.63, p < 0.001). Sensitivity for the pulse check was 99% for both assessments; specificity was 48.9% for a simultaneous assessment and 61.9% for the sequential approach. For breathing check, specificity, sensitivity and accuracy were also higher with the latter method (sensitivity 99.6%, specificity 70.6% and accuracy 88%) Conclusion: A sequential assessment of breathing and pulse by healthcare professionals has greater diagnostic accuracy in simulated case scenarios. © 2005 Elsevier Ireland Ltd. All rights reserved.

Citation

Soar, J., Albarran, J., Moule, P., & Gilchrist, M. (2006). Comparison of sequential and simultaneous breathing and pulse check by healthcare professionals during simulated scenarios. Resuscitation, 68(2), 243-249. https://doi.org/10.1016/j.resuscitation.2005.06.010

Journal Article Type Article
Publication Date Feb 1, 2006
Journal Resuscitation
Print ISSN 0300-9572
Publisher Elsevier
Peer Reviewed Peer Reviewed
Volume 68
Issue 2
Pages 243-249
DOI https://doi.org/10.1016/j.resuscitation.2005.06.010
Keywords basic life support, carotid pulse check, Manikin, breathing check, resuscitation training
Public URL https://uwe-repository.worktribe.com/output/1041262
Publisher URL http://dx.doi.org/10.1016/j.resuscitation.2005.06.010